    FLUKE 17B+ Digital Multimeter w/ Free

    Case Test Leads TL75


    Introduction:


    The Fluke Model 17B+ Multimeters (hereafter referred to as "the Meter") are 4,000 count instruments.
    Maximum Voltage between any Terminal and Earth Ground: 1000 V
    W Fuse Protection for mA µA inputs: 500 mA, 1000 V FAST, Min. Interrupt Rating 20,000 A
    W Fuse Protection for A input: 10 A, 1000 V FAST, Min. Interrupt Rating 20,000 A
    Display: Digital: 4000 count updates 3/sec
    Temperature: Operating: 0 °C to 40 °C,    Storage: -30 °C to 60 °C    indefinitely (to -40 °C for 100 hours)
    Operating Altitude: 0 to 2000 meters
    Temperature Coefficient: 0.1 X (specified accuracy)/ °C (<18    °C or >28 °C)
    Electromagnetic Compatibility: Complies with FCC Part 15, Class B, IEC 61326, 3 V/m, performance    criterion B
    Rated Transient Overvoltage: 4 kV (1.2 x 50 µs) Peak for measurement Categories I, II, and III.
    Relative Humidity: Noncondensing < 10 °C 90% from 10 °C to 30 °C; 75% from 30 °C to 40 °C
    Relative Humidity, 40 MΩ Range: 80% from 10 °C to 30 °C;    70% from 30 °C to 40 °C
    Battery Type: 2 X AA, NEDA 15A, IEC LR6
    Battery Life: Alkaline: 500 Hours
    Size (H x W x L): 180 mm x 89 mm x 51.5 mm (with holster)
    Weight: 425 grams
    Certifications: CMC, P
    Safety Compliance: IEC 61010-1, 2000 CAT I 1000 V, CAT II 600 V, and CAT III 300 V    overvoltage standards
    Overvoltage installation categories per IEC 61010-1, 2000: The Meter is    designed to protect against transients in these catagories:
    CAT I: From high-voltage low-energy sources, e.g., electronic circuits    or a copy machine. CAT II: From equipment supplied from the fixed    installation, e.g., Televisions, PCs, portable tools and household    appliances. CAT III: From equipment in fixed equipment installations, e.g.,    installation panels, feeders and short branch circuits, and lighting systems    in large buildings.
     Digital Multimeter Accuracy Specifications Accuracy Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]) 
    Function Range Resolution Accuracy
    Model 15B Model 17B+
    AC Volts (40 to 500 Hz) v 400.0 mV 1 0.1 mV 3.0 % + 3 3.0 % + 3
    4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3 1.0 % + 3
    DC Millivolts M 400.0 mV 0.1 mV 1.0 % + 10 1.0 % + 10
    DC Volts V 4.000 V 40.00 V 400.0 V 1000 V 0.001 V 0.01 V 0.1 V 1 V 0.5 % + 3 0.5 % + 3
    Diode Test 1.000 V 0.001 V 10 %
    Temperature 3 °C (K-type thermocouple) 50 °C to 400 °C 0    °C to 50 °C -55 °C to 0 °C 0.1 °C NA 2 % + 1 °C ± 2 °C 9 % + 2 °C
    Resistance (Ohms) 400.0 Ω4.000 kΩ40.00    kΩ400.0 kΩ4.000 MΩ40.00 MΩ 0.1 Ω0.001 kΩ0.01    kΩ0.1 kΩ0.001 MΩ0.01 MΩ 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3
    Capacitance 4 c 50.00 nF 500.0 nF 5.000 µF 50.00 µF 100.0 µF 0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5
    Frequency Hz (10 Hz – 100 kHz) 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz NA 0.1 % + 3
    Duty Cycle 0.1 % to 99.9 % 0.1% NA 1% typical 5
    1. Manual Range only 2. Diode test open circuit test voltage is 1.1 V to    1.6 V and short circuit current is < 0.6 mA (typical). 3. Temperature    specifications do not include thermocouple errors. After inserting the    thermocouple plug into the meter, allow several minutes for thermal    stabilization. 4. Specifications do not include errors due to test lead    capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range).    For the 17B, errors can be reduced by using the relative feature. 5. For    values between 10% and 90% duty cycle at 50 Hz.
     
    Function Range Resolution Accuracy
    Model 15B Model 17B+
    AC Current (40 to 200 Hz) 400.0 µA 0.1 µA 1.5 % + 3 1.5 % + 3
      4000 µA 1 µA    
    AC Current (40 to 200 Hz) 40.00 mA 0.01 mA 1.5 % + 3 1.5 % + 3
      400.0 mA 0.1 mA    
    AC Current (40 to 200 Hz) 4.000 A6 10.00 A 0.01 A 0.01 A 1.5 % + 3 1.5 % + 3
    DC Current 400.0 µA 0.1 µA 1.5 % + 3 1.5 % + 3
      4000 µA 1 µA    
    DC Current 40.00 mA 0.01 mA 1.5 % + 3 1.5 % + 3
      400.0 mA 0.1 mA    
             
    DC Current 4.000 A6 0.01 A 1.5 % + 3 1.5 % + 3
      10.00 A 0.01 A    
    6. When in the 4A range, display will show 4000 counts, please ignore    the last digit.  
       
    Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection
    AC Volts v 1000 V >10 MΩ <100 pF >60 dB at dc, 50 or 60 Hz _
    DC Volts V 1000 V >10 MΩ <100 pF >100 dB at dc, 50 or 60 Hz >45 dB at 50 or 60 Hz
    106 V Hz Max        


Additional Information