(0 item) - $0.00

You have no items in your shopping cart.

 

Hantek MSO5202D 200MHz 2 Channel 1GSa/s Oscilloscope 16CH Analyzer Zoom

Hantek MSO5202D 200MHz 2 Channel 1GSa/s Oscilloscope 16CH Analyzer

Be the first to review this product

SKU: DC-OT11238
Hantek MSO5202D 200MHz 2 Channel 1GSa/s Oscilloscope 16CH Analyzer

Availability: In stock

$567.90

With this product, you earn 568 loyalty point(s). 568 points = $5.68.

Product Description

    Details

    Hantek MSO5202D 200MHz 2 Channel 1GSa/s Oscilloscope 16CH Analyzer
    Product Detail

     We Offer EXPRESS Service On This Item.

    Introduction 

    Feature

    • 16 channels logic analyzer + 2 channels oscilloscope + external trigger.
    • Big and clear display (7.0-inch color LCD, high revolution 800 x 480), clear lifelike waveform display.
    • 1GSa/s real time sampling rate.
    • 60MHz-200MHz bandwidth, 1M memory depth.
    • Powerful trigger function.
    • USB host, support flash memory card storage and USB interface system upgrade.
    • Ultrathin design, handy volume, easily portable.

     
    Oscilloscope Function

    • Bandwidth 60MHz-200MHz.
    • Each channel record length up to 1M.
    • Real time sampling rate up to 1GSa/s.
    • Powerful trigger function.
    • More than 20 kinds of automatic measurement function.

     
    Logic Analyzer Function

    • 16 channels divided into 2 groups which is able to setup threshold level individually.
    • Real time sampling rate up to 500MSa/s.
    • Powerful trigger function: edge, duration, pulse width, code-type, queen, repeat.

    Specification

     

    Oscilloscope Specification
    Horizontal
    Model MSO5062D MSO5102D MSO5202D
    Bandwidth 60MHz 100MHz 200MHz
    Sampling Rate Range Max. 1GS/s
    Waveform Interpolation ( sin x) /x
    Memory Depth (Sample Points) Single-channel: maximum 1M; Dual-channel: maximum 512K (4K, 16K, 40K optional)
    SEC/DIV Range 8ns/div-40s/div (stepping in a sequence: 2,4,8)
    Sampling Rate and Delay Time Accuracy ±50ppm in any ≥1ms time intervals
    Delta Time Measurement Accuracy (full bandwidth)  Single, "sampling" mode± (1 sampling interval + 100ppm × readings + 0.6 ns)
    > 16 times above average± (1 sampling interval + 100ppm × readings + 0.4 ns)
    Sampling interval = SEC/DIV÷200
    Vertical
    A/D Converter 8-bit resolution, each channel sampled simultaneously
    VOLTS/DIV Range 2mV/div ~ 5V/div at input BNC
    Position Range ±400mV (2mV/div ~20mV/div)±2V (50mV/div ~200mV/div)±40V (500mV/div ~2V/div)±50V (5V/div)
    Optional Analog Bandwidth Limit (typical) 20MHz
    Low Frequency Response (-3db) ≤10Hz at output BNC
    Rising Time at output BNC (typical) 60MHz 100MHz 200MHz
    ≤ 5.8ns <3.5ns <1.8ns
    Vertical Gain Accuracy ±3% for sample or average acquisition mode, 5V/div to 10mV/div;±4% for sample or average acquisition mode, 5mV/div to 2mV/div
    DC Measurement AccuracyAverage Acquisition Mode Measuring type: ≥16 zero vertical position waveform average .Accuracy: ± (3%× reading+ 0.1div+ 1 mV), applicable to 10 mV/div or above units.
    Measuring type: ≥16 non-zero vertical position waveform average.Accuracy: ± [3%× (readings+ vertical position)+1%×vertical position+0.2div].For the setting from 2mV/div to 200mV/div, +2mV; for 200mV/div to 5V/div, +50mV.
    Voltage Measurement RepeatabilityAverage Acquisition Mode In the same settings and environmental conditions, acquisition ≥ thevoltage increment between any two groups average of 16 above waveforms : ± (3% × readings + 0.05 div)
    Trigger
    Trigger Sensitivity (Edge Trigger Type) Coupling Sensitivity
    DC Source 60MHz 100MHz 200MHz
    CH1CH2 1div from DC to 10MHz, 1.5div from 10MHz to Full 1.5div from 10MHz to 100MHz, 2div from 100MHz to Full
    EXT 200mV from DC to 100MHz 200mV from DC to 100MHz, 350mV from 100MHz to 200MHz
    EXT/5 1V from DC to 100MHz 1V from DC to 100MHz, 1.75V from 100MHz to 200MHz
    AC Attenuates signals below 10Hz
    HF Reject Attenuates signals when above 80kHz
    LF Reject The same as DC coupling limit when frequency above 150kHz; Attenuates signals when below 150kHz.
    Trigger Level Range Source Range
    CH1, CH2 ±8 divisions from center of screen
    EXT ±1.2V
    EXT/5 ±6V
    Trigger Level Accuracy, typical (Accuracy is for signals having rise and fall time ≥ 20ns) Source Accuracy
    CH1, CH2 ±(0.2div × V/div) (within ±4 divisions from center of screen)
    EXT ±(6% of setting+40mV)
    EXT/5 ±(6% of setting+200mV)
    Set Trigger Level to 50% (typical) For the input signals ≥ 50Hz
    Video Trigger Type Source Range
      CH1, CH2 The amplitude of 2 points peak-peak
    EXT 400mV
    EXT/5 2V
    Signal Format , Field Rate and Video Trigger Type Any field or any line support NTSC PAL and SECAM  
    Holdoff Range 100ns-10s  
    Pulse Width Trigger
    Mode When <, >, =, or ≠ trigger; positive or negative pulses.
    Trigger Point =: Triggers when pulse falling edge over trigger level.≠: If the pulse narrower than the appointed width, the trigger point is the falling edge; or triggers when the pulse duration longer than the width setting time.< : Triggers when the pulse duration less than the width setting time.>(Also called overtime trigger): Triggers when pulse is greater than width setting.
    Range 20ns ~10s
    Slope Trigger
    mode When <, >, =, or ≠ trigger; positive or negative slopes.
    Trigger Point =: Triggers when waveform slope is equal to slope setting.≠: Triggers when waveform slope is not equal to slope setting.<: Triggers when waveform slope is less than slope setting.>: Triggers when waveform slope is greater than slope setting.
    Range 20ns-10s
    Overtime Trigger From the rising or falling edge; Setup time: 20-10 s
    Alternative Trigger
    CH1 Internal trigger: edge, pulse, video, or slop
    CH2 Internal trigger: edge, pulse, video, or slop
    Trigger Frequency Counter
    Readout Resolution 6bit
    Accuracy (typical) ±30ppm (Including all of the frequency reference error and ±1 calculation error)
    Frequency Range AC coupling, from minimum 4Hz to specified bandwidth
    Source "Pulse width" or "edge trigger" mode: all available trigger source"Frequency counter" is always measuring the trigger source, even when oscilloscope acquisition paused because of the operation state’s changing, or when a single acquisition finished.The “pulse width" trigger mode: the oscilloscope calculates the pulses whose window having effective amplitude, which measure at 1s and meet trigger condition. For example, if the PWM pulse line is set to < mode, and width is correspondingly set to smaller time, then the narrow pulse among them is the one to be calculated."Edge trigger" mode: the oscilloscope calculates all the edge with sufficient amplitude and correct polarity."Video trigger" mode: "frequency counter" doesn't work.
    Acquisition
    Mode Sample, Peak value detection and Average
    SINGLE SEQ Acquisition Mode Acquisition Stop Time
      Sample, peak value detect All communications start to single acquisition simultaneously
      Average All communications  start to N times acquisition simultaneously, and N could be 4, 8, 16, 32, 64 or 128
    Input
    Input Coupling DC, AC or GND
    Input Impedance, DC Coupling 1MΩ±2% for 20pF±3 pF
    Probe Attenuation 1X, 10X
    Support Probe Attenuation Coefficients  1X, 10X, 100X, 1000X
    Max. Input Voltage Overvoltage Type Max. Voltage
    CAT I and CAT II Installation type: 300VRMS(10×)
    CAT III 150VRMS(1×)
    Installation type Ⅱ: Take 20 dB/decade as slope, from 100kHz above begins to decline to ≥ 3MHz *, the AC peak value is 13V. For the non-sine waveforms, the peak value must less than 450V. Above 300V the offset duration should be less than 100ms. RMS signal level (including all the DC component delete by the AC coupling) must be limited to 300V. If beyond these values, it may damage the device.
    Measurement
    Cursors The difference between voltage cursors △V; the difference between time cursors △T; 1/△T calculated by Hz.
    Automatic Frequency, Period, Mean, Pk-Pk, Cyc RMS, Min, Max, Rise Time, Fall Time, Positive Width, Negative Width.
    General
    Display
    Type 7” TFT, 64K true color LCD
    Resolution 800x480 dots
    Contrast 16 gears with the progress bar to show adjustment
    Probe Compensator Output
    Output Voltage (typical) About 5Vpp input  ≥ 1 M Ω load
    Frequency (typical) 1kHz
    Power Supply
    Voltage 100-120VACRMS(±10%),45Hz to 440Hz, CATⅡ120-240VACRMS(±10%),45Hz to 66Hz, CATⅡ
    Power < 30W
    Fuse 2A, T rating, 250V
    Environment
    Temperature Working: 32℉ to 122℉ (0℃ to 50℃)
    Not working: -40℉ to 159.8℉ (-40℃ to +71℃)
    Cooling Type Convection
    Humidity + 104 ℉ or below (+ 40 ℃ or below) : ≤ 90% relative humidity
    + 106 ℉ to 122℉ (+ 40 ℃ to 50℃) : ≤ 60% relative humidity
    Sea Level Height Working and Not working 3,000m (10,000 foot)
      Random Vibration 50 Hz to 500 Hz: 0.31 g RMS, each axial: 10 minutes
      Not working 5 Hz to 500 Hz: 2.46 g RMS, each axial: 10 minutes
    Mechanical Shock Working 50g, 11ms, half-sine wave
    Mechanical
    Dimension Length 313mm
    Height 142mm
    Thickness 108mm
    Weight Not including the weight of package and accessories 2.08Kg
    Packing Dimension Length 395mm
    Width 410mm
    Height 275mm
    Gross Weight
    Comments
    No comment

    Username
    Email
    Rank  1  2  3  4  5
    Verification code  captcha
    Content
       
Additional Information

    Additional Information

    UPC No
Product's Review

    Write Your Own Review

    You're reviewing: Hantek MSO5202D 200MHz 2 Channel 1GSa/s Oscilloscope 16CH Analyzer

Product Tags

    Use spaces to separate tags. Use single quotes (') for phrases.

CMS tab

You may also be interested in the following product(s)

  • Hantek PPS2116A 110V Programmable USB DC Power Supply 0-5A/0-32V 0.01%+3mV/3mA

    Hantek PPS2116A 110V Programmable USB DC Power Supply 0-5A/0-32V 0.01%+3mV/3mA

    $154.90
  • Hantek HDG2002B Function/Arbitrary Waveform Generator 2 Channels 16Bits 250MSa/s

    Hantek HDG2002B Function/Arbitrary Waveform Generator 2 Channels 16Bits 250MSa/s

    $328.90