(0 item) - $0.00

You have no items in your shopping cart.

 

MeanWell MW DC Switching Power Supply NET-35C 35W 3 o/p 5V 2.5A 15V 1A -15V 0.5A Zoom

MeanWell MW DC Switching Power Supply NET-35C 35W 3 o/p 5V 2.5A 15V 1A -15V 0.5A

Be the first to review this product

SKU: PS-SP11379
Universal AC input/Full range
Protection: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
2 years warranty

Availability: In stock

$29.60

With this product, you earn 30 loyalty point(s). 30 points = $0.30.

Product Description

    Details

     

    MeanWell MW DC Switching Power Supply NET-35C
    (PS-SP11379)

    Features:

    • Universal AC input/Full range
    • Protection: Short circuit / Overload / Over voltage
    • Cooling by free air convection
    • 100% full load burn-in test
    • 2 years warranty

    MODEL

    NET-35C

    OUTPUT

    OUTPUT NUMBER

    CH1

    CH2

    CH3

    DCVOLTAGE

    5V

    15V

    -15V

    RATEDCURRENT

    2.5A

    1A

    0.5A

    CURRENTRANGE

    0.5~3.5A

    0.1-1.5A

    0.1-0.5A

    RATED POWER

    35W

    RIPPLE&NOISENOTE.2

    80MVP-P

    150mVp-p

    150mVp-p

    VOLTAGEADJ.RANGE

    CH1: 4.75~5.5V

    VOLTAGETOLERANCENOTE.3

    ±2.0%

    ±8.0%

    ±8.0%

    LINEREGULATION

    ±0.5%

    ±1.0%

    ±1.0%

    LOADREGULATION

    ±1.5%

    ±3.0%

    ±3.0%

    SETUP.RISEHOLD.TIME

    500ms,30ms/230VAC ,1200ms, 30ms/115VAC at full load

    HOLD TIME

    50ms/230vac  10ms/115vac at full load

    INPUT

    VOLTAGERANGE

    85~264VAC  120~370VDC

    FREQUENCYRANGE

    47~63HZ

    EFFICIENCY

    79%

    AC CURRENT

    0.75A/115vac    0.5A/230VAC

    INRUSH CURRENT

    COLD START 45A

    LEAKAGECURRENT

    <2mA/240VAC

    PROTECTION

    OVERLOAD

    110~150% rated outputpower

    Protection type:Hiccup mode,recovers automatically after fault condition is removed

    OVER VOLTAGE

    CH1:5.75~6.75V

    Protection typeShut odown o/p voltage,re-power on to recover

    ENVIRONMENT

    WORKINGTIMP

    -20~+60°C (Refer to "Derating Curve")

    WORKINGHUMIDITY

    20~90% RH non-condensing

    STORAGE TEMP HUMIDITY

    -40~+85°C 10~95%RH

    TEMPCOEFFICIENT

    ±0.03%/°C (0~45°C )

    VIBRATION

    10~500HZ,2G10min/1cycle period for 60 min each alongX,Y,Zaxes

    SAFETY&EMC

    SAFETYSTANDARDS

    UL60950-1 Approved,CB Approved by TUV(design Refer to IEC 60950-1)

    WITHSTAND VOLTAGE

    1/P-0/P:3KVAC 1/P-FG:2KVAC 0/P-FG:0.5KVAC

    ISOLATIONRESISTANCE

    1/P-0/P,1/P-FG,0/P-FG:100M Ohms/500VDC/25°C/70%RH

    EMI CONDUCTICN&

    Compliance to EN55022(CISPR22) Class B

    RADIATION

    HARMONICCURRENT

    Compliance to EN61000-3-2,-3

    EMS IMMUNITY

    Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204,EN50204,EN61000-6-1 Light industry level criteria A

    QTHERS

    MTBF

    386.2 Khrs min MIL-HDBK-217F(25°C)

    DIMENSION

    99*97*36mm(L*W*H)

    PACKING

    0.36Kg ;45pcs / 17.2Kg / 0.9CUFT

    NOTE

    1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.

    2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

    3. Tolerance : includes set up tolerance, line regulation and load regulation.

    4. Line regulation is measured from low line to high line at rated load.

    5. Load regulation is measured from 0% to 100% rated load.

    6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.For Guidance on how to perform these EMC tests.please refer to "EMI testing of component power supplies"

     

     

    Packing include:

    • MeanWell Power Supply NET-35C  x 1


Additional Information

    Additional Information

    UPC No
Product's Review

    Write Your Own Review

    You're reviewing: MeanWell MW DC Switching Power Supply NET-35C 35W 3 o/p 5V 2.5A 15V 1A -15V 0.5A

Product Tags

    Use spaces to separate tags. Use single quotes (') for phrases.

CMS tab