Product Description
- 180-264VAC input only
- Fully encapsulated with IP67 level (Note.5)
- Protections:Short circuit / Over load / Over voltage / Over temperature
- Cooling by free air convection
- Pass LPS
- 100% full load burn-in test
- Suitable for LED lighting and moving sign applications
- High reliability / Low cost
- 2 years warranty
- Mean Well LPH-18-12 LED Driver x 1
Details
MW Mean Well LPH-18-12 LED Driver 18W 12V IP67 Power Supply
MODEL |
LPH-18-12 |
LPH-18-24 |
LPH-18-36 |
||||||
OUTPUT |
DC VOLTAGE |
12V |
24V |
36V |
|||||
CONSTANT CURRENT VOLTAGE Note7 |
|
||||||||
CURRENT RANGE |
0 ~ 1.5A |
0 ~ 0.75A |
0 ~ 0.5A |
||||||
RATED CURRENT |
1.5A |
0.75A |
0.5A |
||||||
RATED POWER |
18W |
18W |
18W |
||||||
RIPPLE & NOISE (max.) |
120mVp-p |
150mVp-p |
200mVp-p |
||||||
VOLTAGE ADJ. RANGE |
|
||||||||
CURRENT ADJ. RANGE |
|
||||||||
VOLTAGE TOLERANCE |
3.0% |
||||||||
LINE REGULATION |
1.0% |
||||||||
LOAD REGULATION |
2.0% |
||||||||
SETUP, RISE TIME |
1500ms, 30ms / 230VAC |
||||||||
HOLD UP TIME (Typ.) |
50ms/230VAC at full load |
||||||||
INPUT |
VOLTAGE RANGE |
180 ~ 264VAC 254 ~ 370VDC |
|||||||
FREQUENCY RANGE |
47 ~ 63Hz |
||||||||
POWER FACTOR |
|
||||||||
EFFICIENCY (Typ.) |
78% |
82% |
83% |
||||||
AC CURRENT (Typ.) |
0.3A/230VAC |
||||||||
INRUSH CURRENT (Typ.) |
Cold start 50A/230VAC |
||||||||
LEAKAGE CURRENT |
0.25mA / 240VAC |
||||||||
PROTECTION |
OVER CURRENT |
Above 105% rated output power |
|||||||
Protection type : Hiccup mode, recovers automatically after fault |
|||||||||
SHORT CIRCUIT |
|
||||||||
OVER VOLTAGE |
13.8~ 16.2V |
27.6~ 32.4V |
41.4 ~ 48.6V |
||||||
Protection type : Shut off o/p voltage, clamping by zener diode |
|||||||||
OVER TEMPERATURE |
Tj 170 t ypically (U1) Detect on main control IC |
||||||||
Protection type : Hiccup mode, recovers automatically after temperature goes down |
|||||||||
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70 (Refer to output load derating curve) |
|||||||
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
||||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +80 , 10 ~ 95% RH |
||||||||
TEMP. COEFFICIENT |
0.03%/ (0 ~ 50 ) |
||||||||
VIBRATION |
10 ~ 500Hz, 2G 12min./1cycle, period for 60min. each along X, Y, Z axes |
||||||||
SAFETY &EMC (Note 4) |
SAFETY STANDARDS |
TUV EN60950-1, IP67 approved; design refer to UL1310 Class 2,EN61347-2-13, CAN/CSA C22.2 No. 223-M91 |
|||||||
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC |
||||||||
ISOLATION RESISTANCE |
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH |
||||||||
EMI CONDUCTION & |
Compliance to EN55022 (CISPR22) Class B |
||||||||
HARMONIC CURRENT |
Compliance to EN61000-3-2 Class A, EN61000-3-3 |
||||||||
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A |
||||||||
OTHERS |
MTBF |
1200.6K hrs min. MIL-HDBK-217F (25 ) |
|||||||
DIMENSION |
140*30*22(L*W*H) |
||||||||
PACKING |
0.175Kg; 70pcs/13.3Kgs/0.71CUFT |
Additional Information
Additional Information
UPC | No |
---|